Antibiotic stop valve

[Use of the product] 

 Antibiotic shut-off valves are mainly used in biological fermentation, medicine and beer fermentation, amino acid fermentation, biological pesticide fermentation, biological fertilizer fermentation, various antibiotic fermentation, biological, biochemical, chemical and pharmaceutical materials, water, steam, cold control and other fields. The bottom can open excretion holes according to customer needs, which is resistant to high temperatures. Long life, no dead angle to reach the zero leakage level. 

 [Product Features] 

 1. It has strong sterilization and detoxification functions to prevent product contamination. 

 2. The gasket is made of high-temperature-resistant polytetrafluoroethylene composite material. ( The highest temperature can reach ≤120℃) 

 3. The gasket, the middle channel sealing ring of the valve body, and the valve stem packing are all made of high-quality polytetrafluoroethylene material. Long service life, corrosion resistance, ensuring no internal and external leakage. 

 4. The streamlined channel makes the pressure loss small. 

 5. The sealing pad can be replaced, which is more convenient to disassemble and the maintenance cost is low.


Products and services that meet fluid control requirements

Each process, each facility, and each environmental constraint has its own special requirements. Therefore, Dongyan offers a comprehensive range of products covering different performance levels, pressures, different functions and different materials.

Detail

[Design and Manufacturing Standards] 

 Design and Manufacturing: GB/T12235 

 Flange size: JB/T79.1 

 Structural length: GB/T12221 

 Inspection and test: JB/T9092


【 Main Performance Specifications 】

Nominal pressure

1.6 MPa

Test pressure

Strength test

2.4 MPa

Sealing test

1.76 MPa

Upper seal test

1.76 MPa

Gas seal test

0.6 MPa

Maximum operating temperature

120 ℃

Applicable Medium

Water, steam, food, etc


Main appearance and connection dimensions

Nominal diameter

Main appearance and connection dimensions

L

D

D1

D2

b

Z-d

H

D0

J41F-16C

15

130

95

65

45

14-2

4-Φ14

170

120

20

150

105

75

55

14-2

4-Φ14

190

140

25

160

115

85

65

14-2

4-Φ14

205

160

32

180

135

100

78

16-2

4-Φ18

270

180

40

200

145

110

85

16-3

4-Φ18

310

200

50

230

160

125

100

16-3

4-Φ18

358

240

65

290

180

145

120

18-3

4-Φ18

373

240

80

310

195

160

135

20-3

8-Φ18

435

280

100

350

215

180

155

20-3

8-Φ18

500

300

125

400

245

210

185

22-3

8-Φ18

614

320

150

480

280

240

210

24-3

8-Φ23

674

360

200

600

335

295

265

26-3

12-Φ23

811

400

250

650

405

355

320

30-3

12-Φ25

969

450

300

750

460

410

375

30-3

12-Φ25

1145

580

350

850

520

470

435

34-4

16-Φ25

1280

640

400

980

580

525

485

36-4

16-Φ30

1452

640

J41F-25C

15

130

95

65

45

16-2

4-Φ14

170

120

20

150

105

75

55

16-2

4-Φ14

190

140

25

160

115

85

65

16-2

4-Φ14

205

160

32

180

135

100

78

18-2

4-Φ18

270

180

40

200

145

110

85

18-3

4-Φ18

310

200

50

230

160

125

100

20-3

4-Φ18

358

240

65

290

180

145

120

22-3

8-Φ18

373

240

80

310

195

160

135

22-3

8-Φ18

435

280

100

350

230

190

160

24-3

8-Φ23

500

300

125

400

270

220

188

28-3

8-Φ25

614

320

150

480

300

250

218

30-3

8-Φ25

674

360

200

600

360

310

278

34-3

12-Φ25

811

400

250

650

425

370

332

36-3

12-Φ30

969

450

300

750

485

430

390

40-4

16-Φ30

1145

580

350

850

550

490

448

44-4

16-Φ34

1280

640

400

980

610

550

505

48-4

16-Φ34

1452

640


Product Application Scope

These devices are suitable for accurately controlling media such as gases, liquids, steam, etc., and maintaining process parameters such as pressure, flow rate, temperature, and liquid level at given values. Especially suitable for work environments where the allowable pressure difference is small and the allowable leakage is also small, and the pressure difference is not significant.